Part Number Hot Search : 
MNMM02 S3P44R10 Y7C10 MIW5044 2191QL P6KE24A 1N214 T63309A
Product Description
Full Text Search
 

To Download ECP40UT01 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  acdc specification 40 watts ? low profile design ? ultra compact size from 3 x 2 x 0.9 ? it & medical approvals ? single, dual and triple output ? <0.3 w no load input power ? peak load capability ? 3 year warranty ecp series input input voltage ? 85-264 vac input frequency ? 47-63 hz input current ? 0.85 a max at 115 vac inrush current ? 65 a max at 230 vac power factor ? en61000-3-2, class a no load input power ? <0.3 w earth leakage current ? <250 a at 264 vac, 60 hz input protection ? internal t2 a/250 v fuse in line and neutral output output voltage ? see table initial set accuracy ? single output: 1% at 60% load, multiple output: 1% on v1, 5% on v2 & v3 at 60% load minimum load ? 10% minimum load required on v1 & v2 of multi output versions start up delay ? 1.3 s max start up rise time ? 15 ms typical hold up time ? 10 ms min at full load at 115 vac line regulation ? 0.5% max load regulation ? v1 & v3: 2%, v2: 4% (see note 3) cross regulation ? v2: 5%, 10-100% load change on v1 (see note 4) transient response ? 4% max deviation, recovering to less than 1% within 500 s for 50% step load change at 1 a/s ripple & noise ? 1% pk-pk, measured with 20 mhz bandwidth overvoltage protection ? 110-140% of nominal output voltage on v1 only, recycle input to reset overload protection ? single output: 140-160% of nominal power multiple output: 120-150% of nominal power on v1 and v2 only short circuit protection ? trip and restart (hiccup mode) temperature ? 0.02%/c max coefficient xppower.com general efficiency ? see tables isolation ? 4000 vac input to output 1500 vac input to ground 500 vac output to ground switching frequency ? 40-130 khz variable mtbf ? >400 khrs to mil-hdbk-217f at 25 c, gb environmental operating temperature ? -10 c to +70 c, derate from 100% load at 50 c to 50% load at 70 c cooling ? natural convection operating humidity ? 5% to 95% rh, non condensing storage temperature ? -40 c to +85 c shock ? 30 g pk, half sine, 6 axes vibration ? 2 g rms, 5 hz to 500 hz, 3 axes emc & safety emissions ? en55022, level b conducted & radiated harmonic currents ? en61000-3-2, class a voltage flicker ? en61000-3-3 esd immunity ? en61000-4-2, 4 kv indirect contact, perf criteria a radiated immunity ? en61000-4-3, level 2, perf criteria a eft / burst ? en61000-4-4, level 3 perf criteria a surge ? en61000-4-5, installation class 3, perf criteria a conducted immunity ? en61000-4-6, level 3, perf criteria a dips & interruptions ? en61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, perf criteria a, b, b safety approvals ? en60950-1, cul60950, iec60950-1, en60601-1, cul60601-1, iec60601-1
19-feb-13 acdc ecp40 2.75 (69.8) 0.134 (? 3.4) 1.75 (44.5) 2.00 (50.8) 3 1 1 4 0.91 (23.0) 0.79 (19.0) 0.06 (1.6) 0.09 (2.4) cn1 cn2 3.00 (76.2) 0.12 (3.2) 0.12 (3.2) 3.50 (88.9) 1.75 (44.5) 0.134 (? 3.4) 3.25 (82.6) 3 1 1 6 2.0 (50.8) 0.86 (22.0) cn1 cn2 0.12 (3.2) 0.12 (3.2) 0.06 (1.6) 0.09 (2.4) mounting holes need to be isolated from ground mechanical details models and ratings output power output 1 output 2 output 3 efficiency (2) model number voltage current peak (1) voltage current peak (1) voltage current 30 w 5.0 vdc 6.00 a 7.80 a 82% ecp40us05 40 w 12.0 vdc 3.34 a 4.34 a 89% ecp40us12 40 w 15.0 vdc 2.67 a 3.47 a 89% ecp40us15 40 w 18.0 vdc 2.22 a 2.89 a 90% ecp40us18 40 w 24.0 vdc 1.67 a 2.17 a 90% ecp40us24 40 w 30.0 vdc 1.34 a 1.74 a 91% ecp40us30 40 w 48.0 vdc 0.84 a 1.09 a 92% ecp40us48 40 w +5.0 vdc 5.00 a 7.80 a +12.0 vdc 2.0 a 2.60 a 89% ecp40ud01 40 w +5.0 vdc 5.00 a 7.80 a +15.0 vdc 1.5 a 1.95 a 90% ecp40ud02 40 w +5.0 vdc 5.00 a 7.80 a +24.0 vdc 1.0 a 1.30 a 90% ecp40ud03 40 w +5.0 vdc 5.00 a 7.80 a +12.0 vdc 2.0 a 2.60 a -12.0 vdc 0.5 a 89% ECP40UT01 40 w +5.0 vdc 5.00 a 7.80 a +15.0 vdc 1.5 a 1.95 a -15.0 vdc 0.5 a 90% ecp40ut02 40 w +5.0 vdc 5.00 a 7.80 a +24.0 vdc 1.0 a 1.30 a +12.0 vdc 0.5 a 90% ecp40ut03 40 w +5.0 vdc 5.00 a 7.80 a +24.0 vdc 1.0 a 1.30 a -12.0 vdc 0.5 a 90% ecp40ut04 1. all dimensions are in inches (mm). 2. weight: ecp40usxx: 0.18 lbs (80 g) approx, ecp40ud/utxx: 0.24 lbs (110 g) cn1 mates with jst housing vhr-3n and jst series svh-21t-p1.1 crimp terminals. cn2 mates with jst housing vhr-4n and jst series svh-21t-p1.1 crimp terminals. cn1 mates with jst housing vhr-3n and jst series svh-21t-p1.1 crimp terminals. cn2 mates with jst housing vhr-6n and jst series svh-21t-p1.1 crimp terminals. notes 1. peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. 2. typical efficiency at 230 vac and full load at 25 c. 3. for multiple output units, load regulation is given for load change of 10% to 100% with other outputs set to 60% adjustment load. 4. when v2 load is 15-100% notes output connector cn2 pin 1 + vout pin 2 + vout pin 3 - vout pin 4 - vout input connector cn1 pin 1 neutral pin 2 not fitted pin 3 line input connector cn1 pin 1 neutral pin 2 not fitted pin 3 line output connector cn2 pin 1 v2 pin 2 v1 pin 3 v1 pin 4 rtn pin 5 rtn pin 6 v3 ecp40udxx / ecp40utxx ecp40usxx mounting holes marked with must be connected to safety earth mounting holes marked with must be connected to safety earth


▲Up To Search▲   

 
Price & Availability of ECP40UT01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X